All new 360° rectangular diffuser ports provide quiet operation with low system back pressure and 6 PSI pop-off alarm.
New dome lid design incorporates improvements, resulting in high performance with rugged durability. All Salter Bubble humidifiers provide, dependable, cost-effective performance. Ideal for use with all oxygen sources: concentrator, liquid, tank, wall outlet.
360o Rectangular Diffuser ports provide quiet operation with low system back pressure. Dome lid design combines high performance with rugged durability. All Salter bubble humidifiers provide, dependable, cost-effective performance.
Disposable Humidifiers from Salter Labs® are single patient use products designed and engineered for long term durability and complete patient satisfaction.
This Humidifier Connector Adapter Tubing used to attach a humidifier bottle to an oxygen concentrator. The connector tube is 15-inches long with a ribbed oxygen tubing connector one end and a male thread grip on the other end.
Firesafe™ range saves lives by minimising the risk of oxygen-related fires and isolating the oxygen supply, Firesafe™ products are now mandatory in the NHS.
Cannula valves are fitted to each oxygen delivery circuit to stop fires at all danger points in a patient’s supply
Firesafe Protection, Medical Oxygen Concentrators
The requirement to install a minimum of two Firesafe devices (or similar) into a domiciliary Oxygen circuit (one near the chest area and one near the Oxygen source) has been a requirement since 2004/5 under the UK DoH installation specification.
ISO 80601-2-69:2014 is applicable to a transit-operable and non-transit-operable oxygen concentrators and requires a minimum of two Firesafe (or similar) devices fitted to the circuit.
Salter Labs® High Flow Humidifier, 6-15 LPM 350cc Bubble Humidifier-Dry
A new pressure relief valve and all new down spout with 360° rectangular diffuser ports reduces water turbulence and operates quietly.
A pressure relief valve and down spout diffuser design allow high flow delivery (6-15 LPM). This humidifier is specifically suited for applications where delivery via face mask or the Salter-Style® 1600HF cannula require high oxygen flow rates to maintain desired oxygen saturation.
Ideal for use with new generation high capacity output oxygen concentrators, wall outlet source gas or other applications where flow rates up to 15 LPM are required.
All new 360° rectangular diffuser ports provide quiet operation with low system back pressure and 3 PSI pop-off alarm.
New dome lid design incorporates improvements, resulting in high performance with rugged durability. All Salter Bubble humidifiers provide, dependable, cost-effective performance. Ideal for use with all oxygen sources: concentrator, liquid, tank, wall outlet.
360o Rectangular Diffuser ports provide quiet operation with low system back pressure. Dome lid design combines high performance with rugged durability. All Salter bubble humidifiers provide, dependable, cost-effective performance.
Disposable Humidifiers from Salter Labs® are single patient use products designed and engineered for long term durability and complete patient satisfaction.
Angled Male Oxygen Concentrator Outlet, barbed hose adapter, plastic, white, for connection of hoses to humidifier bottles and sterile water
systems, outside thread UNF 9/16“, for 6 mm tubings
To be used to split the flow from an oxygen concentrator from a single outlet to a double outlet. Please note that this will approximately half the flow of the concentrator on each outlet.
Firesafe™ range saves lives by minimising the risk of oxygen-related fires and isolating the oxygen supply, Firesafe™ products are now mandatory in the NHS.
Firesafe Protection, Medical Oxygen Concentrators
The requirement to install a minimum of two Firesafe devices (or similar) into a domiciliary Oxygen circuit (one near the chest area and one near the Oxygen source) has been a requirement since 2004/5 under the UK DoH installation specification.
ISO 80601-2-69:2014 is applicable to a transit-operable and non-transit-operable oxygen concentrators and requires a minimum of two Firesafe (or similar) devices fitted to the circuit.
Built in Fire check in the event of a fire caused by user or other source. Fits Most Oxygen Concentrators
Device Specifications:
Gas Compatibility
Oxygen and oxygen enriched air
Flow Rate
0.7* - 25 l/min
The Firesafe Cannula Valve can be safely used at lower flow rates but may not meet the internal leak rate of 10 ml/min when activated in the event of a fire.
Maximum Operating Pressure
1,000 kPa*
*Maximum static pressure delivered by the gas supply source
Intended Life
8 years after date of manufacture (engraved on device)
Packaging
Packaged in single units
Applied Standards
EN 13544-2:2002 - Respiratory Therapy Equipment - Part 2: Tubing and connectors.
Regulatory
EC: MDD Class IIa Medical Device USA: FDA Class 1 Medical Device; 510(k) exempt Canada: Health Canada licence ref. 78173 Japan: PMDA Class 1 Medical Device Australia: Class IIa, ARTG Indentifier 177167 GMDN Code and Term: 60391 - Fire safety valve
The Firesafe Cannula Valve can be safely used at lower flow rates but may not meet the internal leak rate of 10 ml/min when activated in the event of a fire.
Maximum Operating Pressure
1,000 kPa*
*Maximum static pressure delivered by the gas supply source
Intended Life
8 years after date of manufacture (engraved on device)
Packaging
Supplied in single units
Applied Standards
EN 13544-2:2002 - Respiratory Therapy Equipment - Part 2: Tubing and connectors.
Regulatory
EC: MDD Class IIa Medical Device USA: FDA Class 1 Medical Device; 510(k) exempt Canada: Health Canada licence ref. 78173 Japan: PMDA Class 1 Medical Device Australia: Class IIa, ARTG Indentifier 177167 GMDN Code and Term: 60391 - Fire safety valve
The Firesafe Cannula Valve can be safely used at lower flow rates but may not meet the internal leak rate of 10 ml/min when activated in the event of a fire.
Maximum Operating Pressure
1,000 kPa*
*Maximum static pressure delivered by the gas supply source
Intended Life
8 years after date of manufacture (engraved on device)
Packaging
Supplied in single units
Applied Standards
EN 13544-2:2002 - Respiratory Therapy Equipment - Part 2: Tubing and connectors.
Regulatory
EC: MDD Class IIa Medical Device USA: FDA Class 1 Medical Device; 510(k) exempt Canada: Health Canada licence ref. 78173 Japan: PMDA Class 1 Medical Device Australia: Class IIa, ARTG Indentifier 177167 GMDN Code and Term: 60391 - Fire safety valve